DT Series Copper Cable Lug (Oil Blocking Type)
DT Series copper connecting terminals are pressed from T2 copper bar and tin-plated. The closed oil-stop barrel is sealed at the palm end, so crimped joints on distribution panels and cable runs stay free of moisture and compound.
- Material
- T2 copper bar
- Surface
- Tin-plated
- Wire Range
- 10–630 mm²
- Type
- Oil-stop copper lug
- Standard
- US / Japanese / German
DT Series DT Series Copper Cable Lug (Oil Blocking Type) Specifications
Complete product dimensions and model selection.
| Item No. | Φ (mm) | D (mm) | d (mm) | L (mm) | L1 (mm) | W (mm) | S (mm) |
|---|---|---|---|---|---|---|---|
| DT-10 | 8.5 | 9 | 5.2 | 62 | 26 | 16 | 2.5 |
| DT-16 | 8.5 | 10 | 6.1 | 68 | 30 | 16 | 2.5 |
| DT-25 | 8.5 | 11 | 7.1 | 70 | 33 | 18 | 2.7 |
| DT-35 | 10.5 | 12 | 8.5 | 80 | 36 | 20.5 | 3.0 |
| DT-50 | 10.5 | 14 | 9.8 | 86 | 38 | 23 | 3.4 |
| DT-70 | 12.5 | 16 | 11.5 | 95 | 43 | 26 | 3.8 |
| DT-95 | 12.5 | 18 | 13.5 | 104 | 46 | 28 | 4.2 |
| DT-120 | 14.5 | 20 | 15 | 112 | 49 | 30 | 4.7 |
| DT-150 | 14.5 | 22 | 17 | 120 | 51 | 34 | 5.5 |
| DT-185 | 16.5 | 25 | 18.6 | 126 | 55 | 37 | 5.8 |
| DT-240 | 16.5 | 27 | 21.5 | 137 | 60 | 40 | 6.5 |
| DT-300 | 21 | 31 | 24 | 158 | 68 | 50 | 8.0 |
| DT-400 | 21 | 34 | 27 | 175 | 78 | 50 | 9.0 |
| DT-500 | 21 | 38 | 30 | 186 | 82 | 60 | 10.0 |
| DT-630 | 21 | 45 | 34.2 | 215 | 86 | 80 | 12.0 |
Product Structure & Dimensions
Get a Quote
Send us your wire size, stud size and quantity — we reply within 24 hours.
Looking for DT Series DT Series Copper Cable Lug (Oil Blocking Type)?
Contact our team for product specifications and quotation inquiries.
Frequently Asked Questions
What are DT Series copper cable lugs used for?
DT lugs terminate large stranded copper cable on busbars, breakers, meters and earth bars. The barrel is pressed from T2 copper bar and tin-plated, and the palm carries a standard stud hole for bolted connections.
Which cable sizes does DT cover?
From 10 mm² to 630 mm² in fifteen steps: DT-10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400, 500 and 630. Barrel inner diameter d and palm width W increase with the size, so the lug matches both the cable and the busbar footprint.
What does 'oil-stop' mean in the description?
The barrel is closed at the palm end, so it holds the crimping compound or the cable's own impregnation instead of letting it run through. On paper-insulated or compound-filled cable this prevents the joint from drying out.
How do I choose the stud hole φ?
Match φ to the bolt: φ8.5 mm for M8, φ10.5 mm for M10, φ12.5 mm for M12, φ14.5 mm for M14, φ16.5 mm for M16 and φ21 mm for M20 hardware. A hole much larger than the bolt reduces the contact patch and lets the lug rotate under torque.
How should a DT lug be crimped?
Use a hexagonal or indent crimper with the die marked for the cable size, and crimp from the palm end towards the cable entry. One or two bites depending on barrel length; a correct crimp leaves the barrel straight with no crack at the seam and no die marks on the palm.
What is the difference between DT, DTL and DL?
DT is copper for copper cable, DL is aluminium for aluminium cable, and DTL is a bimetallic copper-aluminium lug used when copper equipment meets aluminium cable. Never bolt a plain copper lug to aluminium cable — the galvanic couple corrodes in damp air.