Twin Wire Insulated Ferrule TE Series
Wire Ferrules TE Series

Twin Wire Insulated Ferrule

TE Series twin wire ferrules accept two conductors in one insulated sleeve, which is the usual way to loop power through a terminal block. The tin-plated copper tube is fitted with a colour-coded nylon sleeve that guides the wires in evenly.

Material
Tin-plated copper tube
Insulation Material
Nylon / PVC
Wire Range
2×22 – 2×6 AWG / 2×0.5 – 2×16 mm²
Insulation Colors
White, Orange, Blue, Red, Yellow, Black, Grey, Green, Brown
Packaging
1000 / 500 / 200 PCS

TE Series Twin Wire Insulated Ferrule Specifications

Complete product dimensions and model selection.

Wire Range Item No. F±0.2 L±0.5 W±0.2 D±0.2 C±0.2 Color Packaging
2×22 AWG
2×0.5 mm²
TE0508 8.0 14.9 5.0 1.8 1.5 White / Orange 1000 PCS
TE0510 10.0 16.9 5.0 1.8 1.5
2×20 AWG
2×0.75 mm²
TE7508 8.0 15.5 5.3 2.1 1.8 Blue / White
TE7510 10.0 17.5 5.3 2.1 1.8
TE7512 12.0 19.5 5.3 2.1 1.8
2×18 AWG
2×1.0 mm²
TE1008 8.0 15.8 5.3 2.4/2.3 2.0 Red / Yellow
TE1010 10.0 17.8 5.3 2.4/2.3 2.0
TE1012 12.0 19.8 5.3 2.4/2.3 2.0
2×16 AWG
2×1.5 mm²
TE1508 8.0 16.5 6.1 2.6 2.3 Black / Red
TE1510 10.0 18.5 6.1 2.6 2.3
TE1512 12.0 20.5 6.1 2.6 2.3
2×14 AWG
2×2.5 mm²
TE2508 8.0 17.8 7.8 3.3 2.9 Grey / Blue
TE2510 10.0 19.8 7.8 3.3 2.9
TE2512 12.0 21.8 7.8 3.3 2.9
2×12 AWG
2×4 mm²
TE4010 10.0 20.3 8.6 4.2 3.8 Orange / Grey
TE4012 12.0 22.3 8.6 4.2 3.8
2×10 AWG
2×6 mm²
TE6012 12.0 23.0 9.5 5.3 4.9 Green / Black 500 PCS
TE6014 14.0 25.0 9.5 5.3 4.9
2×8 AWG
2×10 mm²
TE10-14 14.0 26.0 12.0 6.9 6.5 Brown / White 200 PCS
2×6 AWG
2×16 mm²
TE16-14 14.0 30.6 19.0 8.7 8.3 White / Green

Product Structure & Dimensions

Twin Wire Insulated Ferrule structure and dimensions

Get a Quote

Send us your wire size, stud size and quantity — we reply within 24 hours.

Looking for TE Series Twin Wire Insulated Ferrule?

Contact our team for product specifications and quotation inquiries.

Contact Us

Frequently Asked Questions

What is a TE Series twin ferrule used for?

A twin ferrule puts two conductors into a single insulated sleeve so both land in the same terminal block opening. This is the standard way to loop power from one terminal to the next without doubling the number of clamps.

Which wire combinations does TE cover?

From 2×22 AWG (2×0.5 mm²) up to 2×6 AWG (2×16 mm²), in nine groups. Both conductors must be the same size — the sleeve has two equal bores, and mixing sizes leaves one side loose.

What do the F, L, W, D and C dimensions mean?

F is the insertion depth into the terminal, L the overall length, W the sleeve width, D the barrel diameter and C the bore diameter for each conductor. Check C against your wire size and F against the terminal's clamping depth before ordering.

What do the sleeve colours indicate?

Colour follows the wire range in the same way as single ferrules: white/orange for 2×0.5 mm², blue/white for 2×0.75 mm², red/yellow for 2×1.0 mm², black/red for 2×1.5 mm², grey/blue for 2×2.5 mm², and so on. The colour makes a wrong wire pair visible during inspection.

How do I crimp a twin ferrule without damaging it?

Insert both conductors fully, then crimp with a four-indent or hexagonal die sized to the sleeve — not a single-wire die. A twin ferrule needs the whole sleeve compressed at once; crimping twice distorts the second bore.

Why use one twin ferrule instead of two single ferrules?

Two single ferrules take two terminal openings and can rotate out of position. One twin ferrule occupies a single clamp, keeps both conductors parallel and gives a neater, more repeatable panel build.