Twin Wire Insulated Ferrule
TE Series twin wire ferrules accept two conductors in one insulated sleeve, which is the usual way to loop power through a terminal block. The tin-plated copper tube is fitted with a colour-coded nylon sleeve that guides the wires in evenly.
- Material
- Tin-plated copper tube
- Insulation Material
- Nylon / PVC
- Wire Range
- 2×22 – 2×6 AWG / 2×0.5 – 2×16 mm²
- Insulation Colors
- White, Orange, Blue, Red, Yellow, Black, Grey, Green, Brown
- Packaging
- 1000 / 500 / 200 PCS
TE Series Twin Wire Insulated Ferrule Specifications
Complete product dimensions and model selection.
| Wire Range | Item No. | F±0.2 | L±0.5 | W±0.2 | D±0.2 | C±0.2 | Color | Packaging |
|---|---|---|---|---|---|---|---|---|
| 2×22 AWG 2×0.5 mm² |
TE0508 | 8.0 | 14.9 | 5.0 | 1.8 | 1.5 | White / Orange | 1000 PCS |
| TE0510 | 10.0 | 16.9 | 5.0 | 1.8 | 1.5 | |||
| 2×20 AWG 2×0.75 mm² |
TE7508 | 8.0 | 15.5 | 5.3 | 2.1 | 1.8 | Blue / White | |
| TE7510 | 10.0 | 17.5 | 5.3 | 2.1 | 1.8 | |||
| TE7512 | 12.0 | 19.5 | 5.3 | 2.1 | 1.8 | |||
| 2×18 AWG 2×1.0 mm² |
TE1008 | 8.0 | 15.8 | 5.3 | 2.4/2.3 | 2.0 | Red / Yellow | |
| TE1010 | 10.0 | 17.8 | 5.3 | 2.4/2.3 | 2.0 | |||
| TE1012 | 12.0 | 19.8 | 5.3 | 2.4/2.3 | 2.0 | |||
| 2×16 AWG 2×1.5 mm² |
TE1508 | 8.0 | 16.5 | 6.1 | 2.6 | 2.3 | Black / Red | |
| TE1510 | 10.0 | 18.5 | 6.1 | 2.6 | 2.3 | |||
| TE1512 | 12.0 | 20.5 | 6.1 | 2.6 | 2.3 | |||
| 2×14 AWG 2×2.5 mm² |
TE2508 | 8.0 | 17.8 | 7.8 | 3.3 | 2.9 | Grey / Blue | |
| TE2510 | 10.0 | 19.8 | 7.8 | 3.3 | 2.9 | |||
| TE2512 | 12.0 | 21.8 | 7.8 | 3.3 | 2.9 | |||
| 2×12 AWG 2×4 mm² |
TE4010 | 10.0 | 20.3 | 8.6 | 4.2 | 3.8 | Orange / Grey | |
| TE4012 | 12.0 | 22.3 | 8.6 | 4.2 | 3.8 | |||
| 2×10 AWG 2×6 mm² |
TE6012 | 12.0 | 23.0 | 9.5 | 5.3 | 4.9 | Green / Black | 500 PCS |
| TE6014 | 14.0 | 25.0 | 9.5 | 5.3 | 4.9 | |||
| 2×8 AWG 2×10 mm² |
TE10-14 | 14.0 | 26.0 | 12.0 | 6.9 | 6.5 | Brown / White | 200 PCS |
| 2×6 AWG 2×16 mm² |
TE16-14 | 14.0 | 30.6 | 19.0 | 8.7 | 8.3 | White / Green |
Product Structure & Dimensions
Get a Quote
Send us your wire size, stud size and quantity — we reply within 24 hours.
Looking for TE Series Twin Wire Insulated Ferrule?
Contact our team for product specifications and quotation inquiries.
Frequently Asked Questions
What is a TE Series twin ferrule used for?
A twin ferrule puts two conductors into a single insulated sleeve so both land in the same terminal block opening. This is the standard way to loop power from one terminal to the next without doubling the number of clamps.
Which wire combinations does TE cover?
From 2×22 AWG (2×0.5 mm²) up to 2×6 AWG (2×16 mm²), in nine groups. Both conductors must be the same size — the sleeve has two equal bores, and mixing sizes leaves one side loose.
What do the F, L, W, D and C dimensions mean?
F is the insertion depth into the terminal, L the overall length, W the sleeve width, D the barrel diameter and C the bore diameter for each conductor. Check C against your wire size and F against the terminal's clamping depth before ordering.
What do the sleeve colours indicate?
Colour follows the wire range in the same way as single ferrules: white/orange for 2×0.5 mm², blue/white for 2×0.75 mm², red/yellow for 2×1.0 mm², black/red for 2×1.5 mm², grey/blue for 2×2.5 mm², and so on. The colour makes a wrong wire pair visible during inspection.
How do I crimp a twin ferrule without damaging it?
Insert both conductors fully, then crimp with a four-indent or hexagonal die sized to the sleeve — not a single-wire die. A twin ferrule needs the whole sleeve compressed at once; crimping twice distorts the second bore.
Why use one twin ferrule instead of two single ferrules?
Two single ferrules take two terminal openings and can rotate out of position. One twin ferrule occupies a single clamp, keeps both conductors parallel and gives a neater, more repeatable panel build.